Waveguide termination available from S-Band to Ka-Band.
- Fluid finned or unfinned designs
- Custom designs available
- Silicon carbide machined load inserts available
Peak power capability is approximately equal to the waveguide maximum power rating. The average power ratings are for convection cooled units, these values can be increased by applying water cooling circuits. Designs operating at higher power levels are achievable.
S-Band High Power Water Cooled Load
|
Data Sheet: F0032 |
|
|
|
Electrical Specification
|
| Operating Frequency |
2.6 - 3.95 GHz |
| Bandwidth |
10% Typ. |
| Peak Pulse Power |
7.5 kW Typ. |
| Average Power |
10 kW Typ. |
| Max Input VSWR |
1.2:1 |
| Waveguide Size |
WR284 |
| Cooling Fluid |
Water with/without antifreeze |
| Cooling Fluid Flow Rate |
> 10 L/Minute |
| Operating Temp |
0°C to 35°C |
| Dimensions |
397mm x 115mm x 77mm Typ. |
|
Applications
Microwave Components for:
- Medical
- Security X-ray
- Defence
Features
- S-Band Water Load capable of absorbing 7.5MW peak, 10kW average of reflected RF power
- Options include - E plane probe & pressure release valve
|